{"product_id":"victron-smartsolar-mppt-150-60-tr-scc115060211","title":"Victron SmartSolar MPPT 150\/60-Tr Solar Charge Controller","description":"\u003cdiv class=\"sapphire-product-content\"\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eHigh-Capacity MPPT Solar Charging\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eVictron SmartSolar MPPT 150\/60-Tr Solar Charge Controller\u003c\/strong\u003e is built for larger mobile, marine and off-grid solar systems. It converts energy from a solar array into up to \u003cstrong\u003e60A of battery charging current\u003c\/strong\u003e while supporting 12V, 24V, 36V and 48V battery banks.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eA \u003cstrong\u003e150V maximum PV input\u003c\/strong\u003e provides greater flexibility for series-connected solar panels, helping reduce array current and simplify longer PV cable runs. Built-in Bluetooth makes setup, live monitoring and charging-history review easy through the free VictronConnect app.\u003c\/p\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eWhy You'll Love It\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eUp to 60A of battery charging current\u003c\/li\u003e\n\u003cli\u003e150V maximum PV open-circuit voltage\u003c\/li\u003e\n\u003cli\u003eSupports 12V, 24V, 36V and 48V battery systems\u003c\/li\u003e\n\u003cli\u003eBuilt-in Bluetooth monitoring with the VictronConnect app\u003c\/li\u003e\n\u003cli\u003eAdvanced Maximum Power Point Tracking technology\u003c\/li\u003e\n\u003cli\u003eLarge 35mm² \/ 2 AWG screw terminals for PV and battery wiring\u003c\/li\u003e\n\u003cli\u003eVE.Direct connectivity for GX and VRM system integration\u003c\/li\u003e\n\u003cli\u003eRemote on\/off terminals and a programmable relay\u003c\/li\u003e\n\u003cli\u003eCompatible with the optional SmartSolar Control plug-in display\u003c\/li\u003e\n\u003cli\u003eFanless design with up to 98% peak efficiency\u003c\/li\u003e\n\u003cli\u003eBacked by Victron's 5-year manufacturer's warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eMore Flexibility for Larger Solar Arrays\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe 150V PV input limit allows more panels to be connected in series than with a 100V controller. Higher-voltage strings can reduce PV-side current and voltage drop, which is especially useful on cabins, trailers, boats and remote systems with longer cable runs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eBuilt-in Bluetooth Monitoring\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"victron-app-showcase\"\u003e\n\u003cdiv class=\"victron-app-copy\"\u003e\n\u003cp class=\"sapphire-p\"\u003eBuilt-in Bluetooth gives you direct access to the SmartSolar controller through the free \u003cstrong\u003eVictronConnect\u003c\/strong\u003e app. Check solar production and charging status, review historical performance, configure battery settings and install firmware updates from a compatible phone or tablet.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eView live PV voltage, power and charging current\u003c\/li\u003e\n\u003cli\u003eMonitor battery voltage and charging stage\u003c\/li\u003e\n\u003cli\u003eReview daily solar production history\u003c\/li\u003e\n\u003cli\u003eSelect or customize battery charging profiles\u003c\/li\u003e\n\u003cli\u003eConfigure alarms, relay behaviour and operating settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"victron-app-visual\"\u003e\n\u003cdiv class=\"victron-app-images\"\u003e\n\u003cimg class=\"victron-app-screen victron-app-screen-one\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/mobile_screen_vc5_mppt-100-50-status_800px.webp?v=1785366414\" alt=\"VictronConnect SmartSolar live status screen\" loading=\"lazy\"\u003e\n\u003cimg class=\"victron-app-screen victron-app-screen-two\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/mobile_screen_vc5_mppt-100-50-history_800px.webp?v=1785366414\" alt=\"VictronConnect SmartSolar history screen\" loading=\"lazy\"\u003e\n\u003c\/div\u003e\n\u003cp class=\"victron-app-caption\"\u003eLive status and historical solar production in the free VictronConnect app.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eTypical Solar Array Sizing\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe SmartSolar 150\/60-Tr can deliver up to 60A of charging current. Its nominal PV capacity increases with battery-bank voltage, making it particularly well suited to larger 24V and 48V systems.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003ctd\u003eBattery System\u003c\/td\u003e\n\u003ctd\u003eNominal PV Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12V Battery Bank\u003c\/td\u003e\n\u003ctd\u003e860W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24V Battery Bank\u003c\/td\u003e\n\u003ctd\u003e1720W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36V Battery Bank\u003c\/td\u003e\n\u003ctd\u003e2580W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48V Battery Bank\u003c\/td\u003e\n\u003ctd\u003e3440W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"foot-note\"\u003eThese figures are the controller's nominal PV power ratings. Some array oversizing may be possible, but the complete array must always remain within the controller's voltage and current limits. The array's calculated cold-weather open-circuit voltage must remain below the absolute 150V maximum, and Victron specifies a 145V start-up and operating limit. Panel specifications, wiring arrangement and local minimum temperature must all be considered. Not sure whether your panels are a suitable match? \u003ca class=\"sapphire-link\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\"\u003eContact us for help\u003c\/a\u003e and we will be happy to review your proposed configuration.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/10-awg-solar-panel-pv-extension-cables-w-mc4\" target=\"_blank\" rel=\"noopener\"\u003eView PV Cables\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eTr Screw-Terminal Connections\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eTr\u003c\/strong\u003e version uses heavy-duty screw terminals for both the PV input and battery output rather than factory-installed MC4 connectors. The terminals accept flexible, fine-stranded copper conductors up to \u003cstrong\u003e35mm² \/ 2 AWG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThis arrangement is useful when the controller is installed near breakers, combiner equipment or busbars, and it gives the installer flexibility to select cable sizes and termination methods appropriate for the system.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eTr Does Not Mean MC4\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eSolar-panel leads normally use MC4-style connectors, while this controller has bare-wire screw terminals. Suitable PV extension cable, disconnecting means and circuit protection may be required between the array and controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eBattery Cable \u0026amp; Fuse Recommendations\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAt full output, the controller can supply 60A continuously to the battery bank. Short, properly sized battery cables help reduce voltage drop, heat and charging losses.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003ctd\u003eInstallation Component\u003c\/td\u003e\n\u003ctd\u003eGuidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Capacity\u003c\/td\u003e\n\u003ctd\u003e35mm² \/ 2 AWG flexible copper cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Battery Fuse Range\u003c\/td\u003e\n\u003ctd\u003e70A minimum \/ 80A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd\u003e2.4Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eProtect the Battery Wiring\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eVictron specifies a 70A to 80A battery fuse for the SmartSolar 150\/60. The final fuse and cable size must suit the conductor ampacity, cable length, installation method and applicable electrical requirements. Install the battery fuse close to the positive battery connection.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" target=\"_blank\" rel=\"noopener\"\u003eShop Fuses \u0026amp; Circuit Protection\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eFlexible Battery Charging\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe SmartSolar 150\/60-Tr uses a multi-stage adaptive charging algorithm with pre-programmed profiles and user-adjustable settings. It can be configured for compatible LiFePO₄, flooded lead-acid, AGM and gel battery systems.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eBattery voltage is automatically detected for 12V, 24V and 48V systems. A 36V battery bank is also supported but must be selected manually. Always confirm the charging parameters recommended by the battery manufacturer before commissioning the system.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eOptional Wireless Battery Sensing\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eA compatible Victron Smart Battery Sense, BMV-712 or SmartShunt can share battery voltage and temperature information with the controller through VE.Smart Networking. This can improve charging accuracy when cable voltage drop or changing battery temperature is a concern.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-smartshunt-bluetooth-battery-monitor-300a-500a-1000a-2000a\" target=\"_blank\" rel=\"noopener\"\u003eShop Victron SmartShunts\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eVE.Direct, Remote On\/Off \u0026amp; Programmable Relay\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe integrated VE.Direct port allows the controller to connect to compatible Victron monitoring equipment such as a Cerbo GX. With an internet-connected GX device, solar production and system status can be monitored remotely through the Victron Remote Monitoring portal.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eA two-pole remote on\/off input allows external control by compatible equipment or control systems. The built-in programmable relay can be configured through VictronConnect for alarms or other system-control functions.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eRemember the VE.Direct Cable\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eA VE.Direct cable is required to connect the SmartSolar directly to a Cerbo GX or MPPT Control display. The cable is sold separately and is available in multiple lengths.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-ve-direct-cable\" target=\"_blank\" rel=\"noopener\"\u003eShop VE.Direct Cables\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eOptional Local Display\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eFor at-a-glance information without using a phone, the optional Victron SmartSolar Control display can be installed directly into the front of the controller. The display is sold separately and can be fitted or removed while the controller is operating.\u003c\/p\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eEfficient, Fanless Operation\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWith up to \u003cstrong\u003e98% peak efficiency\u003c\/strong\u003e, the SmartSolar 150\/60-Tr converts available solar energy into battery charging power with minimal loss. Natural cooling eliminates fan noise and reduces moving parts.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe controller can provide its full rated output at ambient temperatures up to \u003cstrong\u003e40°C\u003c\/strong\u003e. At higher temperatures, output may be reduced automatically to protect the controller.\u003c\/p\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eBuilt-In Electronic Protection\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003ePV reverse-polarity protection\u003c\/li\u003e\n\u003cli\u003ePV reverse-current protection\u003c\/li\u003e\n\u003cli\u003eOutput short-circuit protection\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection\u003c\/li\u003e\n\u003cli\u003eAutomatic power reduction at high temperatures\u003c\/li\u003e\n\u003cli\u003eInternal temperature-compensated charging\u003c\/li\u003e\n\u003cli\u003eRecovery charging for deeply discharged batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eCorrect Installation Is Still Required\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eBuilt-in controller protection does not replace properly selected external wiring, fuses, disconnects or overcurrent protection. Solar and battery circuits must remain within the controller's published voltage and current limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eApplications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eLarge RV and motorhome solar systems\u003c\/li\u003e\n\u003cli\u003eBoats and marine battery systems\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and tiny homes\u003c\/li\u003e\n\u003cli\u003eRemote communications and monitoring sites\u003c\/li\u003e\n\u003cli\u003eService and security trailers\u003c\/li\u003e\n\u003cli\u003eHybrid generator and solar systems\u003c\/li\u003e\n\u003cli\u003eBackup and emergency battery systems\u003c\/li\u003e\n\u003cli\u003e12V, 24V, 36V and 48V battery banks\u003c\/li\u003e\n\u003cli\u003eHigher-voltage series-connected solar arrays\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSmartSolar MPPT 150\/60-Tr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSCC115060211\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e12V \/ 24V \/ 48V automatic selection; 36V manual selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Charge Current\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV Power — 12V \/ 24V\u003c\/td\u003e\n\u003ctd\u003e860W \/ 1720W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV Power — 36V \/ 48V\u003c\/td\u003e\n\u003ctd\u003e2580W \/ 3440W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Open-Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e150V absolute maximum; 145V start-up and operating maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 35mA at 12V \/ less than 20mA at 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Absorption Voltage\u003c\/td\u003e\n\u003ctd\u003e14.4V \/ 28.8V \/ 43.2V \/ 57.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Float Voltage\u003c\/td\u003e\n\u003ctd\u003e13.8V \/ 27.6V \/ 41.4V \/ 55.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Algorithm\u003c\/td\u003e\n\u003ctd\u003eMulti-stage adaptive with eight pre-programmed profiles or user-defined settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Bluetooth Smart and VE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eYes, two-pole terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Relay\u003c\/td\u003e\n\u003ctd\u003eDPST; 4A up to 240VAC, 4A up to 35VDC or 1A up to 60VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, up to 35mm² \/ 2 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, up to 35mm² \/ 2 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +60°C; full rated output up to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP43 electronics \/ IP22 connection area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 × 250 × 95mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 62109-1, UL 1741 and CSA C22.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"foot-note\"\u003e\u003cem\u003eSpecifications are believed to be accurate at the time of publication but may change without notice. While we make every effort to keep product information current, Sapphire Energy cannot guarantee all specifications are complete, error-free or up to date. Please refer to the manufacturer's documentation if a particular specification is critical to your application.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-faq\"\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat does “Tr” mean?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe Tr model uses large screw terminals for the PV and battery connections. Solar panels with MC4-style connectors do not plug directly into the controller; the PV cable must be properly terminated at the controller or routed through suitable circuit protection or combining equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I use residential solar panels with the SmartSolar 150\/60-Tr?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The 150V input makes this controller a strong choice for series-connected residential-format solar panels, provided the complete array remains within the controller's voltage and current limits.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe calculated cold-weather open-circuit voltage must remain below the absolute 150V maximum and the 145V start-up and operating limit. The array's total short-circuit current must not exceed 50A. Panel specifications and the minimum expected local temperature must be considered before choosing the final wiring configuration.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\"\u003eContact Us\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I connect more than the nominal PV wattage?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eSome array oversizing may be possible because the controller limits its charging output to 60A. However, the array must always remain within the controller's \u003cstrong\u003e150V absolute maximum open-circuit voltage\u003c\/strong\u003e, \u003cstrong\u003e145V start-up and operating limit\u003c\/strong\u003e and \u003cstrong\u003e50A maximum short-circuit current\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eOversizing should be evaluated using the actual panel specifications, array configuration, battery voltage and coldest expected site temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes the SmartSolar 150\/60-Tr work with LiFePO₄ batteries?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. It can be configured for compatible LiFePO₄ battery banks using VictronConnect. Select or create a charging profile that follows the battery manufacturer's recommended absorption voltage, float voltage and charging limits.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAny required low-temperature charge protection must be provided by the battery's BMS, a compatible external control system or suitable battery-temperature sensing and control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWill it automatically detect my battery voltage?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe controller automatically detects 12V, 24V and 48V battery systems when the battery is connected first and the correct installation sequence is followed. A 36V battery system must be selected manually.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes Bluetooth require an internet connection?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. Your phone or tablet connects directly to the controller through Bluetooth for local setup, monitoring and history review.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eInternet access may be required to download or update VictronConnect, but it is not required for normal local Bluetooth communication.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I connect it to a Cerbo GX for remote monitoring?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. Connect the controller's VE.Direct port to a Cerbo GX using a compatible VE.Direct cable. When the Cerbo GX has internet access and is configured with Victron's VRM portal, the controller can be monitored remotely as part of the larger Victron system.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-ve-direct-cable\" target=\"_blank\" rel=\"noopener\"\u003eShop VE.Direct Cables\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery cable should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eBattery cable must be sized for up to 60A of continuous charging current while keeping voltage drop low. The controller accepts flexible, fine-stranded copper cable up to \u003cstrong\u003e35mm² \/ 2 AWG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe correct conductor size depends on cable length, installation method, insulation temperature rating and applicable electrical requirements. Larger conductors are particularly helpful on 12V systems or longer cable runs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery fuse should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron specifies a \u003cstrong\u003e70A minimum and 80A maximum battery fuse\u003c\/strong\u003e for the SmartSolar 150\/60. The fuse must also be appropriate for the selected battery cable and should be installed close to the battery positive connection.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\"\u003eShop Fuses \u0026amp; Circuit Protection\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I install the controller outdoors?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe electronic components are rated IP43 and the connection area is rated IP22. This is not equivalent to a fully weatherproof outdoor enclosure.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eInstall the controller vertically in a dry, ventilated location protected from direct rain, water spray, condensation and excessive heat. Victron also requires clearance above and below the controller for natural cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat warranty does the SmartSolar MPPT 150\/60-Tr include?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe Victron SmartSolar MPPT 150\/60-Tr is backed by a \u003cstrong\u003e5-year manufacturer's warranty\u003c\/strong\u003e from Victron Energy.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you have a warranty question or need help troubleshooting, Sapphire Energy will assist throughout the warranty process.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" target=\"_blank\" rel=\"noopener\"\u003eContact Us\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eNeed Help Planning Your Solar System?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eTell us which solar panels and battery bank you're using, and we'll help confirm array compatibility, review the proposed series and parallel configuration, and recommend suitable wiring and fuse protection before you order.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" target=\"_blank\" rel=\"noopener\"\u003eContact Us\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55252802502975,"sku":null,"price":496.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/SCC115060211SmartSolar-MPPT-150-60-Tr-_top__2000px.webp?v=1788221023","url":"https:\/\/sapphirebattery.ca\/products\/victron-smartsolar-mppt-150-60-tr-scc115060211","provider":"Sapphire Energy","version":"1.0","type":"link"}