{"product_id":"victron-phoenix-24v-1200va-ve-direct-ul458-gfci-inverter","title":"Victron Phoenix 24V 1200VA VE.Direct Pure Sine Wave Inverter UL458 GFCI","description":"\u003cdiv class=\"sapphire-product-content\"\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eReliable Pure Sine Wave Power\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eVictron Phoenix 24V 1200VA VE.Direct Inverter (UL458)\u003c\/strong\u003e converts power from a 24V battery bank into clean, stable 120V AC power for electronics, chargers, communications equipment and everyday appliances.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eWith up to \u003cstrong\u003e1000W of continuous output at 25°C\u003c\/strong\u003e and \u003cstrong\u003e2200W of peak startup power\u003c\/strong\u003e, it is a dependable choice for RVs, camper vans, boats, service vehicles, cabins and other mobile or off-grid power systems.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThis North American model includes a built-in \u003cstrong\u003eNEMA GFCI receptacle\u003c\/strong\u003e and is certified to \u003cstrong\u003eUL458\u003c\/strong\u003e. Its VE.Direct communication port also supports optional Victron monitoring and configuration accessories.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhy You’ll Love It\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eDesigned for efficient 24V battery systems\u003c\/li\u003e\n\u003cli\u003eClean pure sine wave output for sensitive electronics\u003c\/li\u003e\n\u003cli\u003e1200VA rating with up to 1000W continuous output\u003c\/li\u003e\n\u003cli\u003e2200W peak power for demanding startup loads\u003c\/li\u003e\n\u003cli\u003eBuilt-in North American NEMA GFCI receptacle\u003c\/li\u003e\n\u003cli\u003eVE.Direct port for optional monitoring and configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003ePure Sine Wave Output\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe Phoenix produces a clean AC waveform suitable for sensitive electronics and equipment that may not operate correctly from a basic modified sine wave inverter.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIt is well suited to powering televisions, computers, Starlink equipment, routers, CPAP machines, battery chargers, audio equipment, LED lighting, cordless-tool chargers and other compatible 120V loads.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003e1200VA with 1000W Continuous Output\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThis inverter is rated for 1200VA apparent power and up to 1000W of continuous real-power output at 25°C. Available continuous output is reduced to 850W at an ambient temperature of 40°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eHigh Startup Power\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eMany electronic power supplies, tools and motor-driven loads briefly require more power while starting than they use during normal operation. The Phoenix 24\/1200 can provide up to \u003cstrong\u003e2200W of peak power\u003c\/strong\u003e to help accommodate these short startup demands.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAppliance startup requirements vary significantly. Always compare both the normal operating consumption and startup demand of your equipment with the inverter specifications.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eVE.Direct Connectivity\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe built-in VE.Direct port allows the inverter to communicate with compatible Victron accessories. Using an optional VE.Direct Bluetooth Smart Dongle or VE.Direct-to-USB interface, the inverter can be connected to VictronConnect for basic monitoring and configuration.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eBluetooth is not built directly into this inverter. A compatible VE.Direct interface must be purchased separately.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/pages\/contact\" class=\"sapphire-cta\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eECO Mode\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eECO mode reduces standby consumption when AC power is only needed intermittently. When the connected load drops below the configured level, the inverter enters a low-power search mode and periodically checks for a load.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eECO mode may require adjustment for very small or electronically controlled devices. It can also be disabled when uninterrupted AC output is preferred.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eRecommended Battery Cable and Fuse Sizing\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eProper battery wiring is essential in a 24V inverter system. Cable that is too small or too long can cause excessive voltage drop, reduced surge performance and nuisance low-voltage shutdowns.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Component\u003c\/th\u003e\n\u003cth\u003eRecommendation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Minimum Battery Capacity\u003c\/td\u003e\n\u003ctd\u003e60Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Cable up to 1.5m\u003c\/td\u003e\n\u003ctd\u003e10mm² minimum (8 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Cable from 1.5m to 3m\u003c\/td\u003e\n\u003ctd\u003e16mm² minimum (6 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractical North American Cable Choice\u003c\/td\u003e\n\u003ctd\u003e6 AWG fine-strand copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Fuse\u003c\/td\u003e\n\u003ctd\u003e125A DC fuse (or appropriately rated DC circuit breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eExternal Battery Protection Required\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eVictron requires a suitable fuse or DC circuit breaker to be installed close to the battery for UL-certified NEMA GFCI models, even when the battery cable is less than 1.5m long.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery or combined battery bank must also be capable of supporting the inverter’s operating and startup current. Cable length, installation method, conductor temperature rating and applicable electrical codes may affect final component selection.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eBuilt-In GFCI Outlet\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe integrated North American NEMA GFCI receptacle provides ground-fault protection directly at the inverter output. This makes the UL458 model particularly well suited to RVs, camper vans, marine systems and other mobile power installations.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-sand\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eInverter Only\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe Phoenix converts 24V battery power into 120V AC power. It does not include an AC battery charger or an automatic shore-power transfer switch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eApplications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e24V RV and motorhome electrical systems\u003c\/li\u003e\n\u003cli\u003eCamper vans and vehicle conversions\u003c\/li\u003e\n\u003cli\u003eBoats and marine electrical systems\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and tiny homes\u003c\/li\u003e\n\u003cli\u003eService trucks and mobile workstations\u003c\/li\u003e\n\u003cli\u003eStarlink and remote networking systems\u003c\/li\u003e\n\u003cli\u003eCommunications and HAM radio installations\u003c\/li\u003e\n\u003cli\u003eSolar-powered battery systems\u003c\/li\u003e\n\u003cli\u003eEmergency and portable backup power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Features\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e24V DC battery input\u003c\/li\u003e\n\u003cli\u003ePure sine wave AC output\u003c\/li\u003e\n\u003cli\u003e1200VA continuous apparent-power rating\u003c\/li\u003e\n\u003cli\u003e1000W continuous real-power output at 25°C\u003c\/li\u003e\n\u003cli\u003e2200W peak output\u003c\/li\u003e\n\u003cli\u003e120V AC, 60Hz North American output\u003c\/li\u003e\n\u003cli\u003eBuilt-in NEMA GFCI receptacle\u003c\/li\u003e\n\u003cli\u003eUL458 certified GFCI-output model\u003c\/li\u003e\n\u003cli\u003eVE.Direct communication port\u003c\/li\u003e\n\u003cli\u003eOptional Bluetooth connectivity\u003c\/li\u003e\n\u003cli\u003eLow-power ECO mode\u003c\/li\u003e\n\u003cli\u003eRemote on\/off connection\u003c\/li\u003e\n\u003cli\u003eShort-circuit, overload and temperature protection\u003c\/li\u003e\n\u003cli\u003eIP21 enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePhoenix Inverter 24\/1200 VE.Direct NEMA GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePIN242122510\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18.4V to 34.0V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Apparent Power\u003c\/td\u003e\n\u003ctd\u003e1200VA at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real Power\u003c\/td\u003e\n\u003ctd\u003e1000W at 25°C \/ 850W at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption\u003c\/td\u003e\n\u003ctd\u003e11W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault ECO-Mode Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Receptacle\u003c\/td\u003e\n\u003ctd\u003eNEMA GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Certification\u003c\/td\u003e\n\u003ctd\u003eUL458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eVE.Direct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBluetooth\u003c\/td\u003e\n\u003ctd\u003eOptional with VE.Direct Bluetooth Smart Dongle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connection\u003c\/td\u003e\n\u003ctd\u003eScrew-actuated cage-clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Cable Size\u003c\/td\u003e\n\u003ctd\u003e25mm² (4 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.4kg (16.3lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e117 × 232 × 327mm (4.6 × 9.1 × 12.9in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n    \u003cp class=\"sapphire-p\" style=\"font-size:0.9rem; font-style:italic; color:#6b7280;\"\u003e\n  Specifications are believed to be accurate at the time of publication but may change without notice. While we make every effort to keep product information current, Sapphire Energy cannot guarantee all specifications are complete, error-free or up to date. Please refer to the manufacturer's documentation if a particular specification is critical to your application.\n\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-faq\"\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat can the Phoenix 24\/1200 power?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe Victron Phoenix 24\/1200 provides up to 1000W of continuous real-power output at 25°C using a pure sine wave output. It is ideal for televisions, computers, Starlink equipment, networking gear, CPAP machines, battery chargers, lighting, refrigerators, freezers and many other sensitive electronic devices.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAlways check both the normal running power and startup requirements of the connected equipment. Compressors, pumps, heating appliances and larger motors may require a larger inverter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhy is it called a 1200VA inverter when its output is listed as 1000W?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVA (Volt-Amps) measures apparent power, while watts measure the real power consumed by the connected load. Victron rates this model at 1200VA with a maximum continuous real-power output of 1000W at 25°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat battery cable should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron recommends a minimum of \u003cstrong\u003e10mm² (8 AWG)\u003c\/strong\u003e cable for runs up to 1.5m (5ft), or \u003cstrong\u003e16mm² (6 AWG)\u003c\/strong\u003e cable for runs between 1.5m and 3m (10ft). Keeping the battery cables as short as possible will improve efficiency and reduce voltage drop.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/collections\/battery-cables-jumpers-wiring\" class=\"sapphire-cta\" target=\"_blank\"\u003eShop Battery Cables\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size fuse should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron specifies a \u003cstrong\u003e125A internal DC fuse\u003c\/strong\u003e for the Phoenix 24\/1200. For this UL458 NEMA GFCI model, a suitable external fuse or DC circuit breaker must also be installed as close to the battery positive terminal as practical.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe external protection device must be appropriately rated for the battery voltage, inverter and cable being protected.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/collections\/fuses-circuit-protection\" class=\"sapphire-cta\" target=\"_blank\"\u003eShop Fuses\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery does Victron recommend?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron specifies a minimum battery capacity of \u003cstrong\u003e60Ah\u003c\/strong\u003e for the Phoenix 24\/1200. Larger battery banks will generally provide longer runtime and better support for high-current loads.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery or combined battery bank must also have sufficient continuous and surge discharge capability for the connected inverter load.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I use this inverter with LiFePO₄ batteries?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The Phoenix 24\/1200 works very well with a properly sized 24V LiFePO₄ battery or battery bank. Ensure the battery’s BMS is rated for the inverter’s continuous and surge current requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I use two 12V batteries with this inverter?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. Two compatible 12V batteries can be connected in series to create a 24V battery bank, provided the battery manufacturer permits series operation.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe batteries should be the same model, capacity and age, and should be at a similar state of charge before they are connected in series. Do not connect this 24V inverter directly to a single 12V battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes this inverter have built-in Bluetooth?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. This model includes a VE.Direct communication port but does not have built-in Bluetooth. Wireless monitoring through the VictronConnect app requires the optional VE.Direct Bluetooth Smart Dongle.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you need Bluetooth monitoring, we’re happy to help you select the correct Victron accessory.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/pages\/contact\" class=\"sapphire-cta\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat does the VE.Direct port do?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe VE.Direct port allows the inverter to communicate with compatible Victron monitoring and configuration accessories, including the VE.Direct Bluetooth Smart Dongle, VE.Direct-to-USB Interface, Cerbo GX and other GX monitoring devices.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eNot sure which accessory you need? Contact us and we’ll recommend the right solution for your installation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/pages\/contact\" class=\"sapphire-cta\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it include a battery charger?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The Phoenix is an inverter only. It converts 24V DC battery power into 120V AC power but does not recharge the battery from shore power or a generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you also need battery charging, consider pairing it with a suitable Victron or third-party 24V AC battery charger.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/pages\/contact\" class=\"sapphire-cta\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it include an automatic transfer switch?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. An external transfer switch is required if your AC circuits will be supplied by both the inverter and another AC source such as shore power or a generator.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eIs this the UL-certified GFCI version?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. This model includes a NEMA GFCI receptacle and is certified to \u003cstrong\u003eUL458\u003c\/strong\u003e. The Victron part number is \u003cstrong\u003ePIN242122510\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I hardwire the Phoenix 24\/1200?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The UL458 version of the Phoenix 24\/1200 is designed with a built-in NEMA GFCI receptacle rather than hardwired AC terminals. Simply plug your equipment directly into the inverter or connect an approved extension cord or power strip within the inverter’s rated capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it run a refrigerator or freezer?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eIn many cases, yes. Most modern refrigerators and freezers fall well within the inverter’s 1000W continuous output, but compressor-driven appliances have a higher startup surge that must also be considered.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you’re unsure whether your appliance is compatible, contact us with the make and model number and we’ll be happy to help determine if the Phoenix 24\/1200 is the right fit.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca rel=\"noopener\" href=\"\/pages\/contact\" class=\"sapphire-cta\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I leave the inverter on all the time?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The Victron Phoenix series is designed for continuous operation and is commonly used in RVs, boats, cabins and off-grid systems where power is available around the clock.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eFor maximum battery life, keep your batteries properly charged and remember that even with no AC load connected, the inverter consumes a small amount of power while turned on. If you’re storing your system for an extended period, it’s best to switch the inverter off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":54354072109375,"sku":"PIN242122510","price":439.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/PIN122122510_Inverter12-1200120VVE.DirectNEMAGFCI_rear__1600px.webp?v=1784846746","url":"https:\/\/sapphirebattery.ca\/products\/victron-phoenix-24v-1200va-ve-direct-ul458-gfci-inverter","provider":"Sapphire Energy","version":"1.0","type":"link"}