{"product_id":"victron-multiplus-ii-48-3000-35-50-120v-inverter-charger-pmp482305102","title":"Victron MultiPlus-II 48\/3000\/35-50 120V (UL 1741)","description":"\u003cdiv class=\"sapphire-product-content\"\u003e\n\u003ch1 class=\"sapphire-section-title\"\u003eVictron MultiPlus-II 48\/3000\/35-50 120V Inverter\/Charger\u003c\/h1\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eVictron MultiPlus-II 48\/3000\/35-50 120V\u003c\/strong\u003e combines a pure sine wave inverter, 35A battery charger and 50A automatic transfer switch in one integrated unit. Designed for 48V battery systems, it is an excellent choice for RVs, boats, service vehicles, off-grid cabins and backup-power installations.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen shore power, utility power or a generator is available, the MultiPlus-II passes that power through to connected loads while charging the battery. If the AC source is disconnected or rejected, it changes to inverter power in less than 20 milliseconds—fast enough that most computers and electronic equipment continue operating without interruption.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWhat Does 48\/3000\/35-50 Mean?\u003c\/div\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eWhat It Means\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003eDesigned for a nominal 48V battery bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003ctd\u003e3000VA inverter rating with 2400W continuous real-power output at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003eUp to 35A of battery charging from an available AC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e50A AC input and automatic transfer-switch capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eThis Is the Single-Input 120V Model\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003ePMP482305102 has one 120V AC input and supplies 120V AC output. It is not the MultiPlus-II 2×120V model and does not independently supply 120\/240V split-phase power from a single unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhy You'll Love It\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e3000VA pure sine wave inverter with 2400W continuous output at 25°C\u003c\/li\u003e\n\u003cli\u003eUp to 5500W of short-duration peak power for compatible starting loads\u003c\/li\u003e\n\u003cli\u003e35A adaptive battery charger for 48V battery banks\u003c\/li\u003e\n\u003cli\u003eBuilt-in 50A automatic transfer switch with less than 20ms transfer time\u003c\/li\u003e\n\u003cli\u003ePowerControl and PowerAssist for limited shore-power and generator sources\u003c\/li\u003e\n\u003cli\u003eTwo AC outputs for separating inverter-backed and source-dependent loads\u003c\/li\u003e\n\u003cli\u003eExpandable VE.Bus platform with optional Bluetooth, GX monitoring and remote controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eStrong Starting Power for Demanding Loads\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWith up to \u003cstrong\u003e5500W of peak power\u003c\/strong\u003e, the MultiPlus-II has the short-term output needed to start many compatible refrigerators, pumps, compressors and other motor-driven appliances.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIts continuous inverter rating is 3000VA, with up to 2400W of continuous real-power output at 25°C. This combination provides dependable everyday power along with substantial extra capacity for brief startup surges.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBuilt for Real-World Starting Loads\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eAvailable starting power depends on the appliance, battery condition, BMS discharge rating, DC cable size and voltage drop. A properly designed battery system helps the MultiPlus-II deliver its full starting capability.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Load Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eAutomatic Transfer Between AC and Battery Power\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen an acceptable 120V AC source is connected, the MultiPlus-II transfers that power to AC-out-1 and uses available capacity to charge the battery. If the source fails, is disconnected or falls outside the configured voltage and frequency limits, the inverter automatically takes over.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eTransfer to inverter operation takes less than 20 milliseconds. This makes the MultiPlus-II suitable for applications where refrigerators, communications equipment, computers and other essential loads should continue operating when shore power or generator power is interrupted.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eCharger-Only Mode\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe front switch can be placed in charger-only mode when battery charging and AC passthrough are required but automatic inverter operation is not. If the external AC source disappears, the inverter remains off instead of continuing to power loads from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003ePowerControl \u0026amp; PowerAssist\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerControl\u003c\/strong\u003e allows the maximum AC input current to be adjusted for the connected source. The MultiPlus-II accounts for the power being used by AC loads and reduces battery charging when necessary to avoid overloading a limited shore-power connection or generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerAssist\u003c\/strong\u003e goes one step further. When a temporary load exceeds the available shore or generator capacity, the MultiPlus-II can add inverter power from the battery. Once the load decreases, available AC power can again be used to recharge the battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWorks with Smaller AC Sources\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe 50A rating is the maximum AC input capacity—not the minimum required source size. The input-current limit can be reduced for a compatible 15A, 20A or 30A connection. The setting must match the available source and installed AC protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eTwo AC Outputs for Better Load Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-1\u003c\/strong\u003e is the primary output. It remains powered from the inverter when shore, generator or utility power is unavailable.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-2\u003c\/strong\u003e is a source-dependent auxiliary output rated for up to 32A. It disconnects when the MultiPlus-II changes to battery operation and reconnects after acceptable AC input returns.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThis second output is useful for equipment that should operate only when shore power or a generator is available, such as an electric water heater or another non-essential load that should not discharge the house battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eAC-out-2 Is Not a Second Inverter Circuit\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eAC-out-2 is not powered during battery-only operation. It is specifically intended for loads that should be automatically disabled when the system is running from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003e35A Adaptive Battery Charging\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe built-in charger can supply up to 35A to a compatible nominal 48V battery bank, including suitable 51.2V LiFePO₄ systems. Charging current and voltage settings can be adjusted to meet the requirements of LiFePO₄, AGM, gel and flooded lead-acid batteries.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe four-stage adaptive charging system uses bulk, absorption, float and storage stages. For lead-acid batteries, the adaptive algorithm adjusts absorption time based on the preceding discharge and reduces long-term float voltage when the battery remains unused.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eMaximum 35A battery-charging current\u003c\/li\u003e\n\u003cli\u003eAdjustable charging current and voltage settings\u003c\/li\u003e\n\u003cli\u003eBatterySafe and storage modes for lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eBattery voltage-sense connection for cable-drop compensation\u003c\/li\u003e\n\u003cli\u003eOptional battery temperature sensing with sensor ASS000001000\u003c\/li\u003e\n\u003cli\u003eTwo programmable input\/output ports for compatible BMS integration\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBattery Settings Must Be Confirmed\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe factory charging profile may not be correct for every battery. Charging voltages, maximum current, low-voltage shutdown settings and any required BMS communication must be configured for the installed battery system before regular operation.\u003c\/p\u003e\n  \u003cp class=\"callout-p\"\u003eUse the MK3 USB adapter to connect from your phone or laptop to complete advanced settings programming using the free Victron Connect software\u003c\/p\u003e\n  \n  \u003cdiv class=\"sapphire-cta-group\"\u003e\n    \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-mk3-usb-interface-ve-bus-to-usb\" rel=\"noopener\" target=\"_blank\"\u003eShop the Victron MK3-USB Interface\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eBattery Bank Requirements\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAt full continuous inverter output, a 48V battery system typically supplies approximately 50A to 60A, depending on battery voltage and inverter losses. Starting surges can require considerably more current for a short period.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery bank, internal BMS, busbars, disconnects, fuse and cabling must all be capable of supporting the inverter's continuous and surge current. Victron lists a recommended battery-bank range of approximately 100Ah to 400Ah for this model.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWhy Choose a 48V System?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eFor an equivalent AC load, a 48V system draws approximately half the DC current of a 24V system and one-quarter that of a 12V system. This helps reduce cable losses and the current carried by busbars, disconnects and battery connections.\u003c\/p\u003e\n\u003cp class=\"callout-p\"\u003eAlready using a 24V battery bank? Choose the matching 24V MultiPlus-II for the same 3000VA inverter rating and 2400W continuous output.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-24-3000-70-50-120v-inverter-charger\" rel=\"noopener\" target=\"_blank\"\u003eView the 24V MultiPlus-II\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eMonitoring, Bluetooth \u0026amp; System Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II uses \u003cstrong\u003eVE.Bus\u003c\/strong\u003e for communication and system integration. It does not include built-in Bluetooth or a VE.Direct port.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eMonitoring Option\u003c\/th\u003e\n\u003cth\u003eWhat It Provides\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus Smart Dongle\u003c\/td\u003e\n\u003ctd\u003eOptional local Bluetooth monitoring, on\/off or charger-only control and AC input-current adjustment through VictronConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMK3-USB Interface\u003c\/td\u003e\n\u003ctd\u003eDirect computer connection for detailed VE.Bus configuration and firmware work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Multi Control\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted on\/off or charger-only control with an adjustable AC input-current limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCerbo GX\u003c\/td\u003e\n\u003ctd\u003eCentral system monitoring, Remote Console, optional VRM internet access and integration with other Victron equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBluetooth Is Optional\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II does not connect directly to VictronConnect by Bluetooth. An optional VE.Bus Smart Dongle can add convenient local monitoring and basic control, but it does not replace an MK3-USB interface or compatible GX device for every advanced configuration task.\u003c\/p\u003e\n\u003c\/div\u003e\n\n  \u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n  \u003cdiv class=\"sapphire-callout-title\"\u003eConfigure Your MultiPlus-II with the MK3-USB\u003c\/div\u003e\n  \u003cp class=\"callout-p\"\u003eConnect your MultiPlus-II to a compatible computer using the Victron MK3-USB interface and a VE.Bus RJ45 cable. Use VictronConnect or VEConfigure to adjust battery charging settings, AC input limits and other system parameters. Choose USB-A or USB-C to match your computer—both versions provide the same functionality.\u003c\/p\u003e\n  \u003cdiv class=\"sapphire-cta-group\"\u003e\n    \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-mk3-usb-interface-ve-bus-to-usb\" rel=\"noopener\" target=\"_blank\"\u003eShop the Victron MK3-USB Interface\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eCompatible Generator Integration\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II can accept compatible 120V generator power through its AC input. PowerControl can reduce battery charging to stay within the generator's available output, while PowerAssist can supplement short periods of higher demand from the battery.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe programmable dry-contact relay can also be configured for generator start and stop control. This is generally suitable for a generator or generator controller that accepts a compatible two-wire start signal.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n  \u003cdiv class=\"sapphire-callout-title\"\u003eAutomatic Generator Start \u0026amp; Stop\u003c\/div\u003e\n  \u003cp class=\"callout-p\"\u003eThe MultiPlus-II's programmable relay can control a compatible generator with a two-wire start interface. Use an MK3-USB interface with Victron's configuration software to set up the required generator-control logic.\u003c\/p\u003e\n  \u003cp class=\"callout-p\"\u003eFor more flexible automation, add a Cerbo GX to manage generator operation using conditions such as battery state of charge, voltage or load, along with scheduled runs and quiet hours. The generator must support a compatible remote-start connection.\u003c\/p\u003e\n  \u003cdiv class=\"sapphire-cta-group\"\u003e\n    \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-mk3-usb-interface-ve-bus-to-usb\" rel=\"noopener\" target=\"_blank\"\u003eShop the MK3-USB Interface\u003c\/a\u003e\n    \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eShop the Cerbo GX MK2\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eDC Cabling, Fuse \u0026amp; Installation Planning\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eA 48V battery bank reduces the DC current needed for a given AC load, helping simplify cabling and distribution. Properly sized, low-resistance connections remain essential. Cable length, conductor size, terminal quality, fuse selection and connection torque directly affect starting performance, charging accuracy and system reliability.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eVictron Installation Reference\u003c\/th\u003e\n\u003cth\u003ePublished Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Battery Capacity\u003c\/td\u003e\n\u003ctd\u003e100Ah to 400Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Fuse\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length up to 5m\u003c\/td\u003e\n\u003ctd\u003eOne AWG 1 positive and one AWG 1 negative conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length from 5m to 10m\u003c\/td\u003e\n\u003ctd\u003eOne AWG 2\/0 positive and one AWG 2\/0 negative conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eOne M8 connection point per polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e12Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003eThe values above reproduce Victron's general installation table. Final conductor size, fuse type, disconnects, routing and protection must comply with the complete installation, applicable electrical requirements and the ampacity of the selected cable. Victron specifically states that the battery cables should not be installed in a closed conduit.\u003c\/p\u003e\n\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eProfessional AC Installation Required\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II contains hazardous AC and high-current DC connections. AC input, output, grounding, neutral switching, branch protection and disconnecting equipment must be designed and installed in accordance with the Victron manual and applicable electrical requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 class=\"sapphire-section-title\"\u003eApplications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e48V RV and motorhome house-power systems\u003c\/li\u003e\n\u003cli\u003eCompatible 48V marine house-power systems\u003c\/li\u003e\n\u003cli\u003eService trucks and mobile work trailers\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and small buildings\u003c\/li\u003e\n\u003cli\u003eBackup power for essential 120V loads\u003c\/li\u003e\n\u003cli\u003eGenerator-supported battery systems\u003c\/li\u003e\n\u003cli\u003e48V lithium or lead-acid battery banks\u003c\/li\u003e\n\u003cli\u003eSystems requiring automatic AC transfer\u003c\/li\u003e\n\u003cli\u003eVictron systems using Cerbo GX and VRM monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMultiPlus-II 48\/3000\/35-50 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Part Number\u003c\/td\u003e\n\u003ctd\u003ePMP482305102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e38V to 66V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120VAC ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Rating\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption\u003c\/td\u003e\n\u003ctd\u003e11W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — AES Mode\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — Search Mode\u003c\/td\u003e\n\u003ctd\u003e2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e90V to 140VAC, configurable within supported limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e55Hz to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Input Current\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Switch\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerControl\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerAssist\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Charging Current\u003c\/td\u003e\n\u003ctd\u003e35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Absorption Voltage\u003c\/td\u003e\n\u003ctd\u003e57.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Float Voltage\u003c\/td\u003e\n\u003ctd\u003e55.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Storage Voltage\u003c\/td\u003e\n\u003ctd\u003e52.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Algorithm\u003c\/td\u003e\n\u003ctd\u003eFour-stage adaptive with BatterySafe mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePrimary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-1; inverter-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-2; 32A maximum, available only with external AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Bus through two RJ45 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Bluetooth\u003c\/td\u003e\n\u003ctd\u003eNo; optional VE.Bus Smart Dongle required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Relay\u003c\/td\u003e\n\u003ctd\u003eYes; alarm, low-voltage or compatible generator start\/stop functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Inputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003eTwo analogue\/digital ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\u003ctd\u003eUp to six identical units with appropriate system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eOne M8 connection point per polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals accepting up to 13mm² \/ AWG 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan-assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e147 × 277 × 572mm (5.8 × 10.9 × 22.5in); L = depth, W = width, H = installed height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e19kg \/ 42lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eCertifications\u003c\/td\u003e\n  \u003ctd\u003eUL 458; UL 1741; CSA C22.2 No. 107.1-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd\u003eAdditional Safety Standards\u003c\/td\u003e\n  \u003ctd\u003eEN\/IEC 60335-1; EN\/IEC 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003e\u003cem\u003eSpecifications are believed to be accurate at the time of publication but may change without notice. While we make every effort to keep product information current, Sapphire Energy cannot guarantee all specifications are complete, error-free or up to date. Please refer to the manufacturer’s documentation if a particular specification is critical to your application. \u003ca class=\"sapphire-link\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact us for help!\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-faq\"\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eHow much power can the MultiPlus-II provide?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II can deliver up to \u003cstrong\u003e5500W of peak power\u003c\/strong\u003e to help start compatible refrigerators, pumps, compressors and other loads with a brief startup surge.  \u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eOperating Condition\u003c\/th\u003e\n\u003cth\u003eOutput Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Inverter Rating\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it supply 240V appliances?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eA single unit supplies 120V AC. Two identical units can be configured as a 120\/240V split-phase system to supply compatible 240V appliances.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSplit-phase or multi-phase systems can be created with additional compatible Victron equipment and specialized configuration.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Design Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eShould I choose a 12V, 24V or 48V MultiPlus-II?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eMatch the inverter to your battery bank. The 3000VA models offer the same 2400W continuous output at 25°C, with chargers rated at 120A for 12V, 70A for 24V and 35A for 48V.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eFor a new cabin, tiny-home or backup system, 48V offers lower DC current and convenient integration with compatible 48V storage batteries. Existing RV or marine systems may be better served by a model matching their present battery voltage.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I connect it to a 30A shore-power supply?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The 50A rating is the maximum accepted AC input current. The input-current limit can be reduced to match a compatible 30A or smaller AC source.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eOnce correctly configured, PowerControl reduces charging when necessary to keep the combined charger and AC loads within the selected input limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat happens when shore or generator power fails?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-1 changes to inverter power in less than 20 milliseconds. Most computers and ordinary electronics can continue operating without a noticeable interruption.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-2 switches off because that output is intentionally powered only while an acceptable external AC source is available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it charge lithium batteries?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. It can charge compatible nominal 48V LiFePO₄ batteries, including suitable 51.2V (16-cell) battery banks, when the charging voltages, maximum current, low-voltage settings and any required BMS controls are correctly configured.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery and BMS must also support the inverter's continuous and surge discharge requirements.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Confirming Battery Compatibility\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it include a solar charge controller?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The built-in 35A charger operates from an AC source such as shore power, utility power or a generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSolar panels require a separate appropriately sized solar charge controller connected to the 48V battery system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it have built-in Bluetooth?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The MultiPlus-II communicates through VE.Bus and does not have built-in Bluetooth.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe optional VE.Bus Smart Dongle adds Bluetooth monitoring and basic control through VictronConnect. An MK3-USB interface or compatible GX device is required for certain advanced configuration tasks.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eView Cerbo GX MK2\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Bluetooth Options\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it automatically start a generator?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes, when used with a compatible generator or generator controller that accepts an appropriate two-wire start signal. The MultiPlus-II has a programmable dry-contact relay that can be configured for generator start and stop control.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe relay logic and generator interface must be configured for the specific installation. A Cerbo GX can provide additional generator-control conditions, monitoring and scheduling options.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Generator Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery bank should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's general recommendation for this model is approximately 100Ah to 400Ah at 48V. The correct capacity depends on the required runtime, expected loads, battery chemistry, charging sources and permitted depth of discharge.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eCapacity alone is not enough—the battery BMS must also support the inverter's continuous and peak current requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat battery fuse and cable does Victron specify?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's installation table lists a 125A DC fuse and one AWG 1 positive and one AWG 1 negative conductor for cable lengths up to 5m. For lengths between 5m and 10m, it lists one AWG 2\/0 conductor for each polarity.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThese are manufacturer reference values, not a substitute for installation-specific electrical design. Final cable and fuse selection must account for conductor ampacity, routing, temperature, cable type, local requirements and all connected equipment.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" rel=\"noopener\" target=\"_blank\"\u003eShop Circuit Protection\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Planning the DC System\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan multiple units be connected together?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. Up to six identical units can be configured in parallel for additional capacity. Compatible units can also be used in professionally designed split-phase or three-phase VE.Bus systems.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eMulti-unit systems require identical equipment, matching DC cabling, VE.Bus communication cables and specialized configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n  \u003csummary\u003eCan it be connected to utility power?\u003c\/summary\u003e\n  \u003cdiv class=\"sapphire-faq-body\"\u003e\n    \u003cp class=\"sapphire-p\"\u003eYes. The MultiPlus-II accepts 120V utility power through its AC input to charge the battery and supply connected loads. If utility power fails, AC-out-1 automatically switches to battery-powered inverter operation.\u003c\/p\u003e\n    \u003cp class=\"sapphire-p\"\u003ePMP482305102 is certified to UL 458, UL 1741 and CSA C22.2 No. 107.1-16. However, Victron states that the ESS grid-feed functionality described in its manual is not covered by the UL 1741 or CSA certification. These certifications do not establish approval to export battery or solar power into the utility grid.\u003c\/p\u003e\n    \u003cp class=\"sapphire-p\"\u003eAny proposed grid-parallel or export installation requires confirmation of suitable certified equipment, applicable electrical requirements and utility approval.\u003c\/p\u003e\n    \u003cdiv class=\"sapphire-cta-group\"\u003e\n      \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Your Installation\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n  \u003csummary\u003eHow Do I configure the MultiPlus-II?\u003c\/summary\u003e\n  \u003cdiv class=\"sapphire-faq-body\"\u003e\n    \u003cp class=\"sapphire-p\"\u003eFor direct configuration, use the Victron MK3-USB interface and a VE.Bus RJ45 cable to connect the MultiPlus-II to a compatible Windows or Mac computer, or Android device. The free VictronConnect app lets you adjust charging settings, AC input limits and other supported parameters. An appropriate USB OTG adapter may be required for Android; MK3-USB configuration is not supported on iPhone or iPad.\u003c\/p\u003e\n    \u003cp class=\"sapphire-p\"\u003eMore advanced configuration, including certain Assistants and multi-unit system setup, requires Victron's Windows configuration tools, such as VEConfigure and VE.Bus System Configurator.\u003c\/p\u003e\n    \u003cp class=\"sapphire-p\"\u003eChoose USB-A or USB-C to match your device—both MK3-USB versions provide the same functionality. The interface and VE.Bus RJ45 cable are sold separately.\u003c\/p\u003e\n    \u003cdiv class=\"sapphire-cta-group\"\u003e\n      \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-mk3-usb-interface-ve-bus-to-usb\" rel=\"noopener\" target=\"_blank\"\u003eShop the Victron MK3-USB Interface\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan you special-order other Victron products?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. We may be able to special-order Victron products that are not currently listed on our website, including alternate MultiPlus configurations, monitoring equipment and system accessories.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eContact us with the Victron model or part number you need and we will confirm availability, pricing and estimated lead time.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eRequest a Victron Special Order\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat warranty does this product include?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThis inverter\/charger is backed by Victron Energy's \u003cstrong\u003e5-year limited warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you need troubleshooting or warranty assistance, Sapphire Energy will work with you throughout the process.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003ePlanning a Complete Victron System?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eContact us with your battery specifications, largest AC loads, shore or generator capacity, solar array and required runtime. We can help confirm inverter sizing, battery compatibility, charging capacity, monitoring equipment and the additional wiring and protection required for the installation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Planning Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":67606927638847,"sku":"PMP482305102","price":1323.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/PMP482305102MultiPlus-II48V3kVA_front__2000px.webp?v=1790741014","url":"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-48-3000-35-50-120v-inverter-charger-pmp482305102","provider":"Sapphire Energy","version":"1.0","type":"link"}