{"product_id":"victron-multiplus-ii-24-3000-70-50-120v-inverter-charger","title":"Victron MultiPlus-II 24\/3000\/70-50 120V Inverter\/Charger","description":"\u003cdiv class=\"sapphire-product-content\"\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eInverter, Battery Charger \u0026amp; Automatic Transfer Switch\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eVictron MultiPlus-II 24\/3000\/70-50 120V\u003c\/strong\u003e combines a powerful pure sine wave inverter, a 70A battery charger and a 50A automatic transfer switch in one integrated unit. It is designed for 24V battery systems in RVs, boats, off-grid cabins, tiny homes, service vehicles and backup-power installations.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen shore power, utility power or a generator is available, the MultiPlus-II passes that power through to the connected loads while charging the battery. If the AC source is disconnected or rejected, it automatically changes to inverter power in less than 20 milliseconds—fast enough that most computers and electronic equipment continue operating without interruption.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWhat Does 24\/3000\/70-50 Mean?\u003c\/div\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eWhat It Means\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003eDesigned for a nominal 24V battery bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003ctd\u003e3000VA inverter rating with 2400W continuous real-power output at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003eUp to 70A of battery charging from an available AC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e50A AC input and automatic transfer-switch capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eThis Is a 120V Model\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003ePMP242305102 has one 120V AC input and supplies 120V AC output. It is not the MultiPlus-II 2×120V model and does not independently supply 120\/240V split-phase power from a single unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhy You'll Love It\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e3000VA pure sine wave inverter\u003c\/li\u003e\n\u003cli\u003e2400W continuous output at 25°C\u003c\/li\u003e\n\u003cli\u003eUp to 5500W of short-duration peak power\u003c\/li\u003e\n\u003cli\u003ePowerful 70A adaptive battery charger\u003c\/li\u003e\n\u003cli\u003eBuilt-in 50A automatic transfer switch\u003c\/li\u003e\n\u003cli\u003eLess than 20ms transfer to inverter power\u003c\/li\u003e\n\u003cli\u003ePowerControl prevents overloading limited AC sources\u003c\/li\u003e\n\u003cli\u003ePowerAssist supplements shore or generator power from the battery\u003c\/li\u003e\n\u003cli\u003eSecond AC output for loads that should only operate with external AC available\u003c\/li\u003e\n\u003cli\u003eProgrammable relay for alarms or compatible generator start\/stop control\u003c\/li\u003e\n\u003cli\u003eVE.Bus connectivity for monitoring, configuration and system expansion\u003c\/li\u003e\n\u003cli\u003eCompatible with optional Cerbo GX, remote panels and Bluetooth adapter\u003c\/li\u003e\n\u003cli\u003eSuitable for properly configured lithium and lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eUL 458 listed for mobile and off-grid applications\u003c\/li\u003e\n\u003cli\u003eBacked by Victron's 5-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003e3000VA Does Not Mean 3000W Continuous\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe inverter is rated for \u003cstrong\u003e3000VA\u003c\/strong\u003e, but its continuous real-power rating is \u003cstrong\u003e2400W at 25°C\u003c\/strong\u003e. This distinction is important when comparing inverter sizes or determining whether it can operate a particular appliance.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Condition\u003c\/th\u003e\n\u003cth\u003eOutput Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W \/ 3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"sapphire-p\"\u003eThe strong peak rating helps start compatible refrigerators, pumps, compressors and other motor loads. Successful starting still depends on the appliance, battery condition, BMS discharge rating, cable size and voltage drop within the DC system.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Load Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eAutomatic Transfer Between AC and Battery Power\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen an acceptable 120V AC source is connected, the MultiPlus-II transfers that power to AC-out-1 and uses available capacity to charge the battery. If the source fails, is disconnected or falls outside the configured voltage and frequency limits, the inverter automatically takes over.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eTransfer to inverter operation takes less than 20 milliseconds. This makes the MultiPlus-II suitable for applications where refrigerators, communications equipment, computers and other essential loads should continue operating when shore power or generator power is interrupted.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eCharger-Only Mode\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe front switch can be placed in charger-only mode when battery charging and AC passthrough are required but automatic inverter operation is not. If the external AC source disappears, the inverter remains off instead of continuing to power loads from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003ePowerControl \u0026amp; PowerAssist\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerControl\u003c\/strong\u003e allows the maximum AC input current to be adjusted for the connected source. The MultiPlus-II accounts for the power being used by AC loads and reduces battery charging when necessary to avoid overloading a limited shore-power connection or generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerAssist\u003c\/strong\u003e goes one step further. When a temporary load exceeds the available shore or generator capacity, the MultiPlus-II can add inverter power from the battery. Once the load decreases, available AC power can again be used to recharge the battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWorks with Smaller AC Sources\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe 50A rating is the maximum AC input capacity—not the minimum required source size. The input-current limit can be reduced for a compatible 15A, 20A or 30A connection. The setting must match the available source and the installed AC protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eTwo AC Outputs for Better Load Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-1\u003c\/strong\u003e is the primary output. It remains powered from the inverter when shore, generator or utility power is unavailable.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-2\u003c\/strong\u003e is a source-dependent auxiliary output rated for up to 32A. It disconnects immediately when the MultiPlus-II changes to battery operation and reconnects approximately two minutes after acceptable AC input returns.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThis second output is useful for equipment that should operate only when shore power or a generator is available, such as an electric water heater, large battery charger or other non-essential load that should not discharge the house battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eAC-out-2 Is Not a Second Inverter Circuit\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eAC-out-2 is not powered during battery-only operation. It is specifically intended for loads that should be automatically disabled when the system is running from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003e70A Adaptive Battery Charging\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe built-in charger can supply up to 70A to a compatible 24V battery bank. Charging current and voltage settings can be adjusted to meet the requirements of LiFePO₄, AGM, gel and flooded lead-acid batteries.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe four-stage adaptive charging system uses bulk, absorption, float and storage stages. For lead-acid batteries, the adaptive algorithm adjusts absorption time based on the preceding discharge and reduces long-term float voltage when the battery remains unused.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eMaximum 70A charging current\u003c\/li\u003e\n\u003cli\u003eAdjustable charging current and voltage settings\u003c\/li\u003e\n\u003cli\u003eBatterySafe and storage modes for lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eBattery voltage-sense connection for cable-drop compensation\u003c\/li\u003e\n\u003cli\u003eBattery temperature sensing\u003c\/li\u003e\n\u003cli\u003eTwo programmable input\/output ports for compatible BMS integration\u003c\/li\u003e\n\u003cli\u003e4A maintenance-charging output for a separate 24V starter battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBattery Settings Must Be Confirmed\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe factory charging profile may not be correct for every battery. Charging voltages, maximum current, low-voltage shutdown settings and any required BMS communication must be configured for the installed battery system before regular operation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Confirming Battery Compatibility\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eBattery Bank Requirements\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAt full continuous inverter output, a 24V battery system may need to supply approximately 110A before allowing for changing battery voltage and other installation losses. Starting surges can require considerably more current for a short period.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery bank, internal BMS, busbars, disconnects, fuse and cabling must all be capable of supporting the inverter's continuous and surge current. Victron lists a recommended battery-bank range of approximately 200Ah to 700Ah for this model.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eSuitable for a Properly Rated 24V 200Ah Battery\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eA 24V 200Ah LiFePO₄ battery can be an appropriate match when its BMS discharge rating supports the intended loads and inverter surge current. Available runtime still depends on battery capacity, load size, inverter losses, temperature and the permitted depth of discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eMonitoring, Bluetooth \u0026amp; System Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II uses \u003cstrong\u003eVE.Bus\u003c\/strong\u003e for communication and system integration. It does not include built-in Bluetooth or a VE.Direct port.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMonitoring Option\u003c\/th\u003e\n\u003cth\u003eWhat It Provides\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus Smart Dongle\u003c\/td\u003e\n\u003ctd\u003eOptional local Bluetooth monitoring, on\/off\/charger-only control and AC input-current adjustment through VictronConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMK3-USB Interface\u003c\/td\u003e\n\u003ctd\u003eDirect computer connection for detailed VE.Bus configuration and firmware work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Multi Control\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted on\/off\/charger-only control with adjustable AC input-current limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCerbo GX\u003c\/td\u003e\n\u003ctd\u003eCentral system monitoring, Remote Console, optional internet-connected VRM access and integration with other Victron equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBluetooth Is Optional\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II does not connect directly to VictronConnect by Bluetooth. An optional VE.Bus Smart Dongle can add convenient local monitoring and basic control, but it does not replace an MK3-USB or compatible GX device for every advanced configuration task.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eView Cerbo GX MK2\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Control Accessories\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eCompatible Generator Integration\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II can accept compatible 120V generator power through its AC input. PowerControl can reduce battery charging to stay within the generator's available output, while PowerAssist can supplement short periods of higher demand from the battery.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe programmable dry-contact relay can also be configured for generator start and stop control. This is generally suitable for a generator or generator controller that accepts a compatible two-wire start signal.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eAutomatic Generator Start Requires Configuration\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe relay can be programmed to respond to conditions such as battery voltage, load or battery state. The correct generator interface, control logic and configuration are installation-specific. A Cerbo GX can provide more extensive generator start\/stop conditions and monitoring when required.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Generator Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eDC Cabling, Fuse \u0026amp; Installation Planning\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eA high-power inverter\/charger requires very low-resistance DC connections. Cable length, conductor size, terminal quality, fuse selection and connection torque directly affect starting performance, charging accuracy and system reliability.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVictron Installation Reference\u003c\/th\u003e\n\u003cth\u003ePublished Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Battery Capacity\u003c\/td\u003e\n\u003ctd\u003e200Ah to 700Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Fuse\u003c\/td\u003e\n\u003ctd\u003e300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length up to 5m\u003c\/td\u003e\n\u003ctd\u003eAWG 1\/0 positive and AWG 1\/0 negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length from 5m to 10m\u003c\/td\u003e\n\u003ctd\u003eTwo AWG 1\/0 positive and two AWG 1\/0 negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eTwo M8 studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e12Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003eThe values above reproduce Victron's general installation table. Final conductor size, fuse type, disconnects, routing and protection must comply with the complete installation, applicable electrical requirements and the ampacity of the selected cable. Victron specifically states that the battery cables should not be installed in a closed conduit.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" rel=\"noopener\" target=\"_blank\"\u003eShop Circuit Protection\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Planning the DC System\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eProfessional AC Installation Required\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II contains hazardous AC and high-current DC connections. AC input, output, grounding, neutral switching, branch protection and disconnecting equipment must be designed and installed in accordance with the Victron manual and applicable electrical requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhat Else Is Required?\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II is the inverter, AC charger and transfer switch. It is not a complete electrical system by itself.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eCompatible 24V battery bank\u003c\/li\u003e\n\u003cli\u003eProperly sized battery cables and terminals\u003c\/li\u003e\n\u003cli\u003eBattery-side fuse and disconnect\u003c\/li\u003e\n\u003cli\u003eAppropriate positive and negative DC distribution\u003c\/li\u003e\n\u003cli\u003eAC input and output wiring\u003c\/li\u003e\n\u003cli\u003eRequired AC breakers, disconnects and ground-fault protection\u003c\/li\u003e\n\u003cli\u003eSolar charge controller if solar charging will be used\u003c\/li\u003e\n\u003cli\u003eSolar panels, PV wiring and PV protection as required\u003c\/li\u003e\n\u003cli\u003eOptional monitoring or configuration hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"sapphire-p\"\u003eBattery cables, fuse protection, AC wiring, solar equipment, VE.Bus cables and monitoring accessories are sold separately unless specifically stated otherwise.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eApplications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eOff-grid cabins and tiny homes\u003c\/li\u003e\n\u003cli\u003eRVs, campers and motorhomes\u003c\/li\u003e\n\u003cli\u003eBoats and marine house-power systems\u003c\/li\u003e\n\u003cli\u003eService trucks and mobile work trailers\u003c\/li\u003e\n\u003cli\u003eBackup power for essential 120V loads\u003c\/li\u003e\n\u003cli\u003eGenerator-supported battery systems\u003c\/li\u003e\n\u003cli\u003e24V lithium or lead-acid battery banks\u003c\/li\u003e\n\u003cli\u003eSystems requiring automatic AC transfer\u003c\/li\u003e\n\u003cli\u003eSystems using Cerbo GX and VRM monitoring\u003c\/li\u003e\n\u003cli\u003eExpandable parallel or multi-phase VE.Bus systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMultiPlus-II 24\/3000\/70-50 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Part Number\u003c\/td\u003e\n\u003ctd\u003ePMP242305102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19V to 33V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120VAC ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Rating\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption\u003c\/td\u003e\n\u003ctd\u003e13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — AES Mode\u003c\/td\u003e\n\u003ctd\u003e9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — Search Mode\u003c\/td\u003e\n\u003ctd\u003e3W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e90V to 140VAC, configurable within supported limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e55Hz to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Input Current\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Switch\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerControl\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerAssist\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Charging Current\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Absorption Voltage\u003c\/td\u003e\n\u003ctd\u003e28.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Float Voltage\u003c\/td\u003e\n\u003ctd\u003e27.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Storage Voltage\u003c\/td\u003e\n\u003ctd\u003e26.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Algorithm\u003c\/td\u003e\n\u003ctd\u003eFour-stage adaptive with BatterySafe mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter-Battery Charge Output\u003c\/td\u003e\n\u003ctd\u003e4A maintenance output for a 24V starter battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-1; inverter-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-2; 32A maximum, available only with external AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Bus through two RJ45 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Bluetooth\u003c\/td\u003e\n\u003ctd\u003eNo; optional VE.Bus Smart Dongle required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Relay\u003c\/td\u003e\n\u003ctd\u003eYes; alarm, low-voltage or compatible generator start\/stop functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Inputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003eTwo analogue\/digital ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\u003ctd\u003eUp to six identical units with appropriate system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eTwo M8 studs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals accepting up to 13mm² \/ AWG 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan-assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C; output derates at elevated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e536 × 277 × 147mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e19kg \/ 42lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eUL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 107.1-16; EN\/IEC 60335-1 and EN\/IEC 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003e\u003cem\u003eSpecifications are believed to be accurate at the time of publication but may change without notice. While we make every effort to keep product information current, Sapphire Energy cannot guarantee all specifications are complete, error-free or up to date. Please refer to the manufacturer’s documentation if a particular specification is critical to your application. \u003ca class=\"sapphire-link\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact us for help!\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-faq\"\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eIs the continuous output 3000W?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The inverter is rated at 3000VA, while Victron specifies 2400W of continuous real-power output at 25°C. Continuous output decreases at higher operating temperatures in order to protect the inverter from damage.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eHowever, It can provide substantially more power for short starting surges, with a published peak rating of 5500W, meaning you can start motor loads with ease.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it supply 240V appliances?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNot by itself. This model has a single 120V AC input and produces 120V AC output.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSplit-phase or multi-phase systems can be created with additional compatible Victron equipment and configuration, but that is a system-design project rather than a feature of one standalone unit.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Design Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I connect it to a 30A shore-power supply?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The 50A rating is the maximum accepted AC input current. The input-current limit can be reduced to match a compatible 30A or smaller AC source.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eOnce correctly configured, PowerControl reduces charging when necessary to keep the combined charger and AC loads within the selected input limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat happens when shore or generator power fails?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-1 changes to inverter power in less than 20 milliseconds. Most computers and ordinary electronics can continue operating without a noticeable interruption.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-2 switches off because that output is intentionally powered only while an acceptable external AC source is available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat is the second AC output used for?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-2 is intended for loads that should operate only when shore, utility or generator power is available. It disconnects during battery operation so those loads cannot discharge the house battery.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eCommon examples include an electric water heater or another large non-essential load. AC-out-2 is rated for a maximum of 32A and requires appropriate external protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it charge lithium batteries?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. It can charge compatible 24V LiFePO₄ batteries when the charging voltages, maximum current, low-voltage settings and any required BMS controls are correctly configured.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery and BMS must also support the inverter's continuous and surge discharge requirements.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Confirming Battery Compatibility\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it include a solar charge controller?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The built-in 70A charger operates from an AC source such as shore power, utility power or a generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSolar panels require a separate appropriately sized solar charge controller connected to the 24V battery system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it have built-in Bluetooth?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The MultiPlus-II communicates through VE.Bus and does not have built-in Bluetooth.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe optional VE.Bus Smart Dongle adds Bluetooth monitoring and basic control through VictronConnect. A Cerbo GX can provide more complete system monitoring, Remote Console and optional VRM internet access.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eView Cerbo GX MK2\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Bluetooth Options\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it automatically start a generator?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes, when used with a compatible generator or generator controller that accepts an appropriate two-wire start signal. The MultiPlus-II has a programmable dry-contact relay that can be configured for generator start and stop control.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe relay logic and generator interface must be configured for the specific installation. A Cerbo GX can provide additional generator-control conditions, monitoring and scheduling options.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Generator Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery bank should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's general recommendation for this model is approximately 200Ah to 700Ah at 24V. The correct capacity depends on the required runtime, expected loads, battery chemistry, charging sources and permitted depth of discharge.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eCapacity alone is not enough—the battery BMS must also support the inverter's continuous and peak current requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat battery fuse and cable does Victron specify?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's installation table lists a max 300A DC fuse and AWG 1\/0 positive and negative battery cables for cable lengths up to 5m. For lengths between 5m and 10m, it lists two parallel AWG 1\/0 conductors for each polarity.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThese are manufacturer reference values, not a substitute for installation-specific electrical design. Final cable and fuse selection must account for conductor ampacity, routing, temperature, cable type, local requirements and all connected equipment.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" rel=\"noopener\" target=\"_blank\"\u003eShop Circuit Protection\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Planning the DC System\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan multiple units be connected together?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. Up to six identical units can be configured in parallel for additional capacity. Compatible units can also be used in professionally designed split-phase or three-phase VE.Bus systems.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eMulti-unit systems require identical equipment, matching DC cabling, VE.Bus communication cables and specialized configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it be connected to utility power?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eYes—for incoming power and battery backup, but not as a grid-tied solar inverter.\u003c\/strong\u003e The MultiPlus-II can receive 120V utility power through its AC input, pass that power through to connected loads and use it to charge the battery. If utility power fails, it can automatically switch AC-out-1 to battery-powered inverter operation.\u003c\/p\u003e\n\n\u003cp class=\"sapphire-p\"\u003eThe PMP242305102 is UL 458 listed for mobile, marine, off-grid and backup-power applications. Although the MultiPlus-II platform supports bidirectional operation, this model's grid-feed functionality is \u003cstrong\u003enot UL 1741 or CSA grid-interconnection certified\u003c\/strong\u003e. It should therefore not be used to export battery or solar power back into the utility grid as a standalone grid-tie inverter.\u003c\/p\u003e\n\n\u003cp class=\"sapphire-p\"\u003eAny system intended to operate in parallel with—or export power to—a utility grid must use the required certified equipment and be designed in accordance with local electrical codes, utility requirements and approval from the applicable authority.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat warranty does this product include?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThis inverter\/charger is backed by Victron Energy's \u003cstrong\u003e5-year limited warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you need troubleshooting or warranty assistance, Sapphire Energy will work with you throughout the process.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003ePlanning a Complete Victron System?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eContact us with your battery specifications, largest AC loads, shore or generator capacity, solar array and required runtime. We can help confirm inverter sizing, battery compatibility, charging capacity, monitoring equipment and the additional wiring and protection required for the installation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Planning Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55058935251263,"sku":"PMP242305102","price":1399.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/MultiPlus-II24V3kVA_front__2000px.webp?v=1785981422","url":"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-24-3000-70-50-120v-inverter-charger","provider":"Sapphire Energy","version":"1.0","type":"link"}