{"product_id":"victron-multiplus-ii-12-3000-120-50-120v-inverter-charger-pmp122305122","title":"Victron MultiPlus-II 12\/3000\/120-50 120V Inverter\/Charger","description":"\u003cdiv class=\"sapphire-product-content\"\u003e\n\u003ch1 class=\"sapphire-section-title\"\u003eVictron MultiPlus-II 12\/3000\/120-50 120V Inverter\/Charger\u003c\/h1\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe \u003cstrong\u003eVictron MultiPlus-II 12\/3000\/120-50 120V\u003c\/strong\u003e combines a pure sine wave inverter, powerful 120A battery charger and 50A automatic transfer switch in one integrated unit. Designed for 12V battery systems, it is an excellent choice for RVs, boats, service vehicles, off-grid cabins and backup-power installations.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen shore power, utility power or a generator is available, the MultiPlus-II passes that power through to connected loads while charging the battery. If the AC source is disconnected or rejected, it changes to inverter power in less than 20 milliseconds—fast enough that most computers and electronic equipment continue operating without interruption.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWhat Does 12\/3000\/120-50 Mean?\u003c\/div\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eWhat It Means\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eDesigned for a nominal 12V battery bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003ctd\u003e3000VA inverter rating with 2400W continuous real-power output at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003eUp to 120A of battery charging from an available AC source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e50A AC input and automatic transfer-switch capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eThis Is the Single-Input 120V Model\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003ePMP122305122 has one 120V AC input and supplies 120V AC output. It is not the MultiPlus-II 2×120V model and does not independently supply 120\/240V split-phase power from a single unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhy You'll Love It\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003e3000VA pure sine wave inverter with 2400W continuous output at 25°C\u003c\/li\u003e\n\u003cli\u003eUp to 5500W of short-duration peak power for compatible starting loads\u003c\/li\u003e\n\u003cli\u003ePowerful 120A adaptive battery charger for 12V battery banks\u003c\/li\u003e\n\u003cli\u003eBuilt-in 50A automatic transfer switch with less than 20ms transfer time\u003c\/li\u003e\n\u003cli\u003ePowerControl and PowerAssist for limited shore-power and generator sources\u003c\/li\u003e\n\u003cli\u003eTwo AC outputs for separating inverter-backed and source-dependent loads\u003c\/li\u003e\n\u003cli\u003eExpandable VE.Bus platform with optional Bluetooth, GX monitoring and remote controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eStrong Starting Power for Demanding Loads\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWith up to \u003cstrong\u003e5500W of peak power\u003c\/strong\u003e, the MultiPlus-II has the short-term output needed to start many compatible refrigerators, pumps, compressors and other motor-driven appliances.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIts continuous inverter rating is 3000VA, with up to 2400W of continuous real-power output at 25°C. This combination provides dependable everyday power along with substantial extra capacity for brief startup surges.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBuilt for Real-World Starting Loads\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eAvailable starting power depends on the appliance, battery condition, BMS discharge rating, DC cable size and voltage drop. A properly designed battery system helps the MultiPlus-II deliver its full starting capability.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Load Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eAutomatic Transfer Between AC and Battery Power\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eWhen an acceptable 120V AC source is connected, the MultiPlus-II transfers that power to AC-out-1 and uses available capacity to charge the battery. If the source fails, is disconnected or falls outside the configured voltage and frequency limits, the inverter automatically takes over.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eTransfer to inverter operation takes less than 20 milliseconds. This makes the MultiPlus-II suitable for applications where refrigerators, communications equipment, computers and other essential loads should continue operating when shore power or generator power is interrupted.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eCharger-Only Mode\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe front switch can be placed in charger-only mode when battery charging and AC passthrough are required but automatic inverter operation is not. If the external AC source disappears, the inverter remains off instead of continuing to power loads from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003ePowerControl \u0026amp; PowerAssist\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerControl\u003c\/strong\u003e allows the maximum AC input current to be adjusted for the connected source. The MultiPlus-II accounts for the power being used by AC loads and reduces battery charging when necessary to avoid overloading a limited shore-power connection or generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003ePowerAssist\u003c\/strong\u003e goes one step further. When a temporary load exceeds the available shore or generator capacity, the MultiPlus-II can add inverter power from the battery. Once the load decreases, available AC power can again be used to recharge the battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eWorks with Smaller AC Sources\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe 50A rating is the maximum AC input capacity—not the minimum required source size. The input-current limit can be reduced for a compatible 15A, 20A or 30A connection. The setting must match the available source and installed AC protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eTwo AC Outputs for Better Load Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-1\u003c\/strong\u003e is the primary output. It remains powered from the inverter when shore, generator or utility power is unavailable.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eAC-out-2\u003c\/strong\u003e is a source-dependent auxiliary output rated for up to 32A. It disconnects when the MultiPlus-II changes to battery operation and reconnects after acceptable AC input returns.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThis second output is useful for equipment that should operate only when shore power or a generator is available, such as an electric water heater or another non-essential load that should not discharge the house battery.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eAC-out-2 Is Not a Second Inverter Circuit\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eAC-out-2 is not powered during battery-only operation. It is specifically intended for loads that should be automatically disabled when the system is running from the battery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003e120A Adaptive Battery Charging\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe built-in charger can supply up to 120A to a compatible 12V battery bank. Charging current and voltage settings can be adjusted to meet the requirements of LiFePO₄, AGM, gel and flooded lead-acid batteries.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe four-stage adaptive charging system uses bulk, absorption, float and storage stages. For lead-acid batteries, the adaptive algorithm adjusts absorption time based on the preceding discharge and reduces long-term float voltage when the battery remains unused.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eMaximum 120A battery-charging current\u003c\/li\u003e\n\u003cli\u003eAdjustable charging current and voltage settings\u003c\/li\u003e\n\u003cli\u003eBatterySafe and storage modes for lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eBattery voltage-sense connection for cable-drop compensation\u003c\/li\u003e\n\u003cli\u003eBattery temperature sensing\u003c\/li\u003e\n\u003cli\u003eTwo programmable input\/output ports for compatible BMS integration\u003c\/li\u003e\n\u003cli\u003eMaintenance-charging output for a separate 12V starter battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBattery Settings Must Be Confirmed\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe factory charging profile may not be correct for every battery. Charging voltages, maximum current, low-voltage shutdown settings and any required BMS communication must be configured for the installed battery system before regular operation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Confirming Battery Compatibility\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eBattery Bank Requirements\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAt full continuous inverter output, a 12V battery system may need to supply more than 200A after allowing for battery voltage and inverter losses. Starting surges can require considerably more current for a short period.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery bank, internal BMS, busbars, disconnects, fuse and cabling must all be capable of supporting the inverter's continuous and surge current. Victron lists a recommended battery-bank range of approximately 400Ah to 1200Ah for this model.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003ePrefer Lower DC Current?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe 24V MultiPlus-II provides the same 3000VA inverter rating and 2400W continuous output while drawing roughly half as much DC current for an equivalent AC load. A 24V system may simplify battery, BMS, busbar and cable planning in higher-power installations.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-24-3000-70-50-120v-inverter-charger\" rel=\"noopener\" target=\"_blank\"\u003eView the 24V MultiPlus-II\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eMonitoring, Bluetooth \u0026amp; System Control\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II uses \u003cstrong\u003eVE.Bus\u003c\/strong\u003e for communication and system integration. It does not include built-in Bluetooth or a VE.Direct port.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eMonitoring Option\u003c\/th\u003e\n\u003cth\u003eWhat It Provides\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus Smart Dongle\u003c\/td\u003e\n\u003ctd\u003eOptional local Bluetooth monitoring, on\/off or charger-only control and AC input-current adjustment through VictronConnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMK3-USB Interface\u003c\/td\u003e\n\u003ctd\u003eDirect computer connection for detailed VE.Bus configuration and firmware work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Multi Control\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted on\/off or charger-only control with an adjustable AC input-current limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCerbo GX\u003c\/td\u003e\n\u003ctd\u003eCentral system monitoring, Remote Console, optional VRM internet access and integration with other Victron equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eBluetooth Is Optional\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II does not connect directly to VictronConnect by Bluetooth. An optional VE.Bus Smart Dongle can add convenient local monitoring and basic control, but it does not replace an MK3-USB interface or compatible GX device for every advanced configuration task.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eView Cerbo GX MK2\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Control Accessories\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eCompatible Generator Integration\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II can accept compatible 120V generator power through its AC input. PowerControl can reduce battery charging to stay within the generator's available output, while PowerAssist can supplement short periods of higher demand from the battery.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe programmable dry-contact relay can also be configured for generator start and stop control. This is generally suitable for a generator or generator controller that accepts a compatible two-wire start signal.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eAutomatic Generator Start Requires Configuration\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe relay can be programmed to respond to conditions such as battery voltage or load. The correct generator interface, control logic and configuration are installation-specific. A Cerbo GX can provide more extensive generator start\/stop conditions and monitoring when required.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Generator Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eDC Cabling, Fuse \u0026amp; Installation Planning\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eA 3000VA inverter operating from a 12V battery bank requires extremely low-resistance DC connections. Cable length, conductor size, terminal quality, fuse selection and connection torque directly affect starting performance, charging accuracy and system reliability.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eVictron Installation Reference\u003c\/th\u003e\n\u003cth\u003ePublished Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Battery Capacity\u003c\/td\u003e\n\u003ctd\u003e400Ah to 1200Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Fuse\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length up to 5m\u003c\/td\u003e\n\u003ctd\u003eTwo AWG 1\/0 positive and two AWG 1\/0 negative conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Cable Length from 5m to 10m\u003c\/td\u003e\n\u003ctd\u003eTwo AWG 2\/0 positive and two AWG 2\/0 negative conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eTwo M8 connection points per polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e12Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003eThe values above reproduce Victron's general installation table. Final conductor size, fuse type, disconnects, routing and protection must comply with the complete installation, applicable electrical requirements and the ampacity of the selected cable. Victron specifically states that the battery cables should not be installed in a closed conduit.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" rel=\"noopener\" target=\"_blank\"\u003eShop Circuit Protection\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Planning the DC System\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-yellow\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003eProfessional AC Installation Required\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eThe MultiPlus-II contains hazardous AC and high-current DC connections. AC input, output, grounding, neutral switching, branch protection and disconnecting equipment must be designed and installed in accordance with the Victron manual and applicable electrical requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eWhat Else Is Required?\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II is the inverter, AC charger and transfer switch. It is not a complete electrical system by itself.\u003c\/p\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eCompatible 12V battery bank with sufficient discharge capacity\u003c\/li\u003e\n\u003cli\u003eProperly sized battery cables, terminals and busbars\u003c\/li\u003e\n\u003cli\u003eBattery-side fuse and suitably rated disconnect\u003c\/li\u003e\n\u003cli\u003eAppropriate positive and negative DC distribution\u003c\/li\u003e\n\u003cli\u003eAC input and output wiring with required protection\u003c\/li\u003e\n\u003cli\u003eSeparate solar charge controller if solar charging will be used\u003c\/li\u003e\n\u003cli\u003eOptional monitoring or configuration hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"sapphire-p\"\u003eBattery cables, fuse protection, AC wiring, solar equipment, VE.Bus cables and monitoring accessories are sold separately unless specifically stated otherwise.\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eApplications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cul class=\"sapphire-checklist\"\u003e\n\u003cli\u003eRVs, campers and motorhomes\u003c\/li\u003e\n\u003cli\u003eBoats and marine house-power systems\u003c\/li\u003e\n\u003cli\u003eService trucks and mobile work trailers\u003c\/li\u003e\n\u003cli\u003eOff-grid cabins and small buildings\u003c\/li\u003e\n\u003cli\u003eBackup power for essential 120V loads\u003c\/li\u003e\n\u003cli\u003eGenerator-supported battery systems\u003c\/li\u003e\n\u003cli\u003e12V lithium or lead-acid battery banks\u003c\/li\u003e\n\u003cli\u003eSystems requiring automatic AC transfer\u003c\/li\u003e\n\u003cli\u003eVictron systems using Cerbo GX and VRM monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMultiPlus-II 12\/3000\/120-50 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron Part Number\u003c\/td\u003e\n\u003ctd\u003ePMP122305122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Battery Voltage\u003c\/td\u003e\n\u003ctd\u003e12V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9.5V to 17V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120VAC ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e60Hz ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Rating\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption\u003c\/td\u003e\n\u003ctd\u003e13W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — AES Mode\u003c\/td\u003e\n\u003ctd\u003e9W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero-Load Consumption — Search Mode\u003c\/td\u003e\n\u003ctd\u003e3W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e90V to 140VAC, configurable within supported limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccepted AC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e55Hz to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Input Current\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Switch\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eLess than 20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerControl\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerAssist\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Battery Charging Current\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Absorption Voltage\u003c\/td\u003e\n\u003ctd\u003e14.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Float Voltage\u003c\/td\u003e\n\u003ctd\u003e13.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Storage Voltage\u003c\/td\u003e\n\u003ctd\u003e13.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Algorithm\u003c\/td\u003e\n\u003ctd\u003eFour-stage adaptive with BatterySafe mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter-Battery Charge Output\u003c\/td\u003e\n\u003ctd\u003eMaintenance-charging output for a separate 12V starter battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-1; inverter-backed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary AC Output\u003c\/td\u003e\n\u003ctd\u003eAC-out-2; 32A maximum, available only with external AC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eVE.Bus through two RJ45 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Bluetooth\u003c\/td\u003e\n\u003ctd\u003eNo; optional VE.Bus Smart Dongle required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Relay\u003c\/td\u003e\n\u003ctd\u003eYes; alarm, low-voltage or compatible generator start\/stop functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Inputs\/Outputs\u003c\/td\u003e\n\u003ctd\u003eTwo analogue\/digital ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\u003ctd\u003eUp to six identical units with appropriate system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connections\u003c\/td\u003e\n\u003ctd\u003eTwo M8 connection points per polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Connections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals accepting up to 13mm² \/ AWG 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFan-assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C; output derates at elevated temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e578 × 277 × 148mm \/ 22.8 × 10.9 × 5.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e19kg \/ 42lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eUL 458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 107.1-16; EN\/IEC 60335-1 and EN\/IEC 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"foot-note\"\u003e\u003cem\u003eSpecifications are believed to be accurate at the time of publication but may change without notice. While we make every effort to keep product information current, Sapphire Energy cannot guarantee all specifications are complete, error-free or up to date. Please refer to the manufacturer’s documentation if a particular specification is critical to your application. \u003ca class=\"sapphire-link\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact us for help!\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003chr class=\"sapphire-hr\"\u003e\n\u003cdiv class=\"sapphire-faq\"\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eHow much power can the MultiPlus-II provide?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThe MultiPlus-II can deliver up to \u003cstrong\u003e5500W of peak power\u003c\/strong\u003e to help start compatible refrigerators, pumps, compressors and other loads with a brief startup surge.  \u003c\/p\u003e\n\u003cdiv class=\"sapphire-table-wrap\"\u003e\n\u003ctable class=\"sapphire-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"sapphire-spec-header\"\u003e\n\u003cth\u003eOperating Condition\u003c\/th\u003e\n\u003cth\u003eOutput Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output\u003c\/td\u003e\n\u003ctd\u003e5500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Inverter Rating\u003c\/td\u003e\n\u003ctd\u003e3000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 25°C\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Real-Power Output at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it supply 240V appliances?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNot by itself. This model has a single 120V AC input and produces 120V AC output.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSplit-phase or multi-phase systems can be created with additional compatible Victron equipment and specialized configuration.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Design Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eShould I choose the 12V or 24V version?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eChoose the version that matches the nominal voltage of your battery bank. The two versions provide the same 3000VA inverter rating and 2400W continuous output, but the 12V version has a 120A charger while the 24V version has a 70A charger.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eFor the same AC load, the 24V version draws roughly half the DC current. This can reduce the demands placed on the battery BMS, busbars and DC cabling.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-24-3000-70-50-120v-inverter-charger\" rel=\"noopener\" target=\"_blank\"\u003eView the 24V MultiPlus-II\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan I connect it to a 30A shore-power supply?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. The 50A rating is the maximum accepted AC input current. The input-current limit can be reduced to match a compatible 30A or smaller AC source.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eOnce correctly configured, PowerControl reduces charging when necessary to keep the combined charger and AC loads within the selected input limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat happens when shore or generator power fails?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-1 changes to inverter power in less than 20 milliseconds. Most computers and ordinary electronics can continue operating without a noticeable interruption.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAC-out-2 switches off because that output is intentionally powered only while an acceptable external AC source is available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it charge lithium batteries?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. It can charge compatible 12V LiFePO₄ batteries when the charging voltages, maximum current, low-voltage settings and any required BMS controls are correctly configured.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe battery and BMS must also support the inverter's continuous and surge discharge requirements.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Confirming Battery Compatibility\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it include a solar charge controller?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The built-in 120A charger operates from an AC source such as shore power, utility power or a generator.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eSolar panels require a separate appropriately sized solar charge controller connected to the 12V battery system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eDoes it have built-in Bluetooth?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eNo. The MultiPlus-II communicates through VE.Bus and does not have built-in Bluetooth.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe optional VE.Bus Smart Dongle adds Bluetooth monitoring and basic control through VictronConnect. An MK3-USB interface or compatible GX device is required for certain advanced configuration tasks.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/products\/victron-cerbo-gx-mk2-system-monitoring-hub\" rel=\"noopener\" target=\"_blank\"\u003eView Cerbo GX MK2\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eAsk About Bluetooth Options\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it automatically start a generator?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes, when used with a compatible generator or generator controller that accepts an appropriate two-wire start signal. The MultiPlus-II has a programmable dry-contact relay that can be configured for generator start and stop control.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThe relay logic and generator interface must be configured for the specific installation. A Cerbo GX can provide additional generator-control conditions, monitoring and scheduling options.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for Generator Compatibility Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat size battery bank should I use?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's general recommendation for this model is approximately 400Ah to 1200Ah at 12V. The correct capacity depends on the required runtime, expected loads, battery chemistry, charging sources and permitted depth of discharge.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eCapacity alone is not enough—the battery BMS must also support the inverter's continuous and peak current requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat battery fuse and cable does Victron specify?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eVictron's installation table lists a 400A DC fuse and two AWG 1\/0 positive and two AWG 1\/0 negative conductors for cable lengths up to 5m. For lengths between 5m and 10m, it lists two AWG 2\/0 conductors for each polarity.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eThese are manufacturer reference values, not a substitute for installation-specific electrical design. Final cable and fuse selection must account for conductor ampacity, routing, temperature, cable type, local requirements and all connected equipment.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\n\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/collections\/fuses-circuit-protection\" rel=\"noopener\" target=\"_blank\"\u003eShop Circuit Protection\u003c\/a\u003e \u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eGet Help Planning the DC System\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan multiple units be connected together?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. Up to six identical units can be configured in parallel for additional capacity. Compatible units can also be used in professionally designed split-phase or three-phase VE.Bus systems.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eMulti-unit systems require identical equipment, matching DC cabling, VE.Bus communication cables and specialized configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan it be connected to utility power?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003e\u003cstrong\u003eYes—for incoming power and battery backup, but not as a grid-tied solar inverter.\u003c\/strong\u003e The MultiPlus-II can receive 120V utility power through its AC input, pass that power through to connected loads and use it to charge the battery. If utility power fails, it can automatically switch AC-out-1 to battery-powered inverter operation.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003ePMP122305122 is UL 458 listed for mobile, marine, off-grid and backup-power applications. It is not UL 1741 listed for utility grid interconnection and should not be used to export battery or solar power into the utility grid as a standalone grid-tie inverter.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eAny system intended to operate in parallel with—or export power to—a utility grid must use the required certified equipment and comply with local electrical codes, utility requirements and applicable approvals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eCan you special-order other Victron products?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eYes. We may be able to special-order Victron products that are not currently listed on our website, including alternate MultiPlus configurations, monitoring equipment and system accessories.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eContact us with the Victron model or part number you need and we will confirm availability, pricing and estimated lead time.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eRequest a Victron Special Order\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"sapphire-faq-item\"\u003e\n\u003csummary\u003eWhat warranty does this product include?\u003c\/summary\u003e\n\u003cdiv class=\"sapphire-faq-body\"\u003e\n\u003cp class=\"sapphire-p\"\u003eThis inverter\/charger is backed by Victron Energy's \u003cstrong\u003e5-year limited warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"sapphire-p\"\u003eIf you need troubleshooting or warranty assistance, Sapphire Energy will work with you throughout the process.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n\u003cdiv class=\"sapphire-callout-title\"\u003ePlanning a Complete Victron System?\u003c\/div\u003e\n\u003cp class=\"callout-p\"\u003eContact us with your battery specifications, largest AC loads, shore or generator capacity, solar array and required runtime. We can help confirm inverter sizing, battery compatibility, charging capacity, monitoring equipment and the additional wiring and protection required for the installation.\u003c\/p\u003e\n\u003cdiv class=\"sapphire-cta-group\"\u003e\u003ca class=\"sapphire-cta\" href=\"https:\/\/sapphirebattery.ca\/pages\/contact\" rel=\"noopener\" target=\"_blank\"\u003eContact Us for System Planning Help\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55698703417663,"sku":null,"price":1262.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/MultiPlus-II24V3kVA_front__2000px_ad5b9117-2ef9-4a1f-babd-b4b758f3edbf.webp?v=1790191277","url":"https:\/\/sapphirebattery.ca\/products\/victron-multiplus-ii-12-3000-120-50-120v-inverter-charger-pmp122305122","provider":"Sapphire Energy","version":"1.0","type":"link"}