{"product_id":"insulated-wire-ferrules-18mm-tinned-copper","title":"Wire Ferrules - Insulated Tinned Copper","description":"\u003cdiv class=\"sapphire-product-description\"\u003e\n  \u003ch2 class=\"sapphire-title\"\u003eWeidmüller UL 18 mm Insulated Wire Ferrules\u003c\/h2\u003e\n  \u003chr class=\"sapphire-hr\"\u003e\n  \u003cp class=\"sapphire-p\"\u003eFinish stranded copper conductors with genuine \u003cstrong\u003eWeidmüller insulated wire-end ferrules\u003c\/strong\u003e. Their extended \u003cstrong\u003e18 mm tinned copper sleeves\u003c\/strong\u003e suit compatible \u003cstrong\u003eVictron MultiPlus-II AC wiring terminals\u003c\/strong\u003e that specify an 18 mm ferrule.\u003c\/p\u003e\n  \u003cp class=\"sapphire-p\"\u003eAvailable in \u003cstrong\u003e10 AWG (6 mm²), 8 AWG (10 mm²), and 6 AWG (16 mm²)\u003c\/strong\u003e, with colour-coded insulating collars. These ferrules are included in Weidmüller's \u003cstrong\u003eUL 486F certified crimping system\u003c\/strong\u003e (file E499744).\u003c\/p\u003e\n\n  \u003ch3 class=\"sapphire-section-title\"\u003eWhy You’ll Love It\u003c\/h3\u003e\n  \u003chr class=\"sapphire-hr\"\u003e\n  \u003cul class=\"sapphire-checklist\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003e18 mm metal sleeve\u003c\/strong\u003e — fits compatible Victron MultiPlus-II terminals that specify extended wire ferrules.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUL 486F certification\u003c\/strong\u003e — part of Weidmüller's certified ferrule-and-tool system, UL file E499744.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTinned copper sleeve\u003c\/strong\u003e — good electrical conductivity and corrosion resistance.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eClean stranded-wire termination\u003c\/strong\u003e — helps capture individual strands for insertion into suitable terminals.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInsulated, colour-coded collar\u003c\/strong\u003e — facilitates conductor entry and size identification.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThree useful wire sizes\u003c\/strong\u003e — 10 AWG, 8 AWG, and 6 AWG.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 class=\"sapphire-section-title\"\u003eSpecifications\u003c\/h3\u003e\n  \u003chr class=\"sapphire-hr\"\u003e\n  \u003cdiv class=\"sapphire-table-wrap\"\u003e\n  \u003ctable class=\"sapphire-spec-table\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eWeidmüller\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eStyle\u003c\/th\u003e\n\u003ctd\u003eSingle-wire insulated ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eSleeve material\u003c\/th\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMetal sleeve length\u003c\/th\u003e\n\u003ctd\u003e18 mm (0.71 in), excluding plastic collar\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003e10 AWG \/ 6 mm²\u003c\/th\u003e\n\u003ctd\u003e0565700000 · black collar · 26 mm overall\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003e8 AWG \/ 10 mm²\u003c\/th\u003e\n\u003ctd\u003e9019250000 · red collar · 28 mm overall\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003e6 AWG \/ 16 mm²\u003c\/th\u003e\n\u003ctd\u003e9019270000 · blue collar · 28 mm overall\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eUL standard\u003c\/th\u003e\n\u003ctd\u003eUL 486F (certified crimping system)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eUL certification file\u003c\/th\u003e\n\u003ctd\u003eE499744\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sapphire-callout sapphire-callout-blue\"\u003e\n    \u003cdiv class=\"sapphire-callout-title\"\u003eFor Victron MultiPlus-II AC Connections\u003c\/div\u003e\n    \u003cp class=\"callout-p\"\u003eThe \u003cstrong\u003e18 mm\u003c\/strong\u003e specification refers to the metal sleeve only, not the collar or overall ferrule length. Confirm conductor size and ferrule requirements in the installation manual for your exact inverter model.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch3 class=\"sapphire-section-title\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n  \u003chr class=\"sapphire-hr\"\u003e\n  \u003cdiv class=\"sapphire-faq\"\u003e\n    \u003cdetails class=\"sapphire-faq-item\"\u003e\n      \u003csummary\u003eWhy do some Victron MultiPlus-II models need 18 mm ferrules?\u003c\/summary\u003e\n      \u003cdiv class=\"sapphire-faq-body\"\u003e\n        \u003cp class=\"sapphire-p\"\u003eCertain MultiPlus-II AC terminals specify an extended 18 mm sleeve. Ordinary short ferrules may not meet that terminal's installation instructions. Measure the metal sleeve, not the plastic collar, and follow the manual for your exact unit.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails class=\"sapphire-faq-item\"\u003e\n      \u003csummary\u003eAre these ferrules UL certified?\u003c\/summary\u003e\n      \u003cdiv class=\"sapphire-faq-body\"\u003e\n        \u003cp class=\"sapphire-p\"\u003eThese Weidmüller ferrules are included in a UL 486F certified crimping system under file \u003cstrong\u003eE499744\u003c\/strong\u003e. Certification depends on using an approved ferrule-and-crimping-tool combination; it does not apply automatically to every tool or crimp.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails class=\"sapphire-faq-item\"\u003e\n      \u003csummary\u003eCan I use these ferrules outside of Victron installations?\u003c\/summary\u003e\n      \u003cdiv class=\"sapphire-faq-body\"\u003e\n        \u003cp class=\"sapphire-p\"\u003eYes, where the equipment accepts the chosen conductor size and an insulated ferrule with an 18 mm metal sleeve. Use a suitable ferrule crimping tool and follow the terminal manufacturer's instructions.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmüller","offers":[{"title":"#10 AWG (6mm²)","offer_id":67731955712319,"sku":"FER-10AWG-18-WM","price":1.0,"currency_code":"CAD","in_stock":false},{"title":"#8 AWG (10mm²)","offer_id":67731955745087,"sku":"FER-08AWG-18-WM","price":1.25,"currency_code":"CAD","in_stock":false},{"title":"#6 AWG (16mm²)","offer_id":67731955777855,"sku":"FER-06AWG-18-WM","price":1.25,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6803\/8463\/files\/10_to_6awg_ferrule_render_color_1600px.webp?v=1792002563","url":"https:\/\/sapphirebattery.ca\/products\/insulated-wire-ferrules-18mm-tinned-copper","provider":"Sapphire Energy","version":"1.0","type":"link"}